"Enhancing Precision and Efficiency: Discover the Power of Single Point Load Cells"
Model No.: LP80
Brand: XG
Place Of Origin: China
Series: LP80
Features: Single load cell, Small Size
Mounting Type: Parallel beam installation
Description: Small size single load cell, load cell
Type: Load Cell
Place Of Origin: Guangdong, China
Brand Name: XG sengsor
Usage: Weighing sensor, Weight
Theory: Resistance, Resistance Sensor
Product Name: Loadcell
Packaging: The inner packing is pallet, the outer carton is carton
Transportation: Ocean,Land,Air,Express,Others
Place of Origin: China
Supply Ability: 10000 Piece/Day
Port: sheng zhen
Payment Type: T/T,L/C,D/P,Paypal,Others
Incoterm: FOB,CIF
Introducing our state-of-the-art Single Point Load Cell, designed to revolutionize the way weight measurements are conducted in various industries. This high-precision load cell boasts exceptional accuracy, with a maximum capacity of X kilograms/pounds, ensuring precise and reliable weight readings. Its compact design allows for easy integration into existing systems, making it an ideal choice for applications such as industrial weighing scales, packaging machinery, and material handling equipment. Built with robust materials, this load cell guarantees long-lasting performance even in harsh environments. With its advanced technology and unparalleled precision, our Single Point Load Cell is the ultimate solution for accurate weight measurements, enabling businesses to optimize efficiency and enhance productivity.
Single Point Load Laod Cell
Choosing the right Single Point Load Laod Cell needs to consider many factors, and customized selection according to application requirements can better meet actual needs. If you need to choose Single Point Load Laod Cell.
Suggestions for reference
1. Measuring range: First, you need to select the load range to be measured, and ensure that the selected Single Point Load Laod Cell has the corresponding measurement capability within this range.
2. Accuracy requirements: According to the level of the load to be monitored, determine the oscillation and nonlinear error requirements, as well as other details such as acceptable error accuracy and sensitivity.
3. Environmental adaptability: When selecting a Single Point Load Laod Cell suitable for the working environment, consider the influencing factors of temperature, dust, humidity, electromagnetic interference and lateral force. It should be noted that the more unfavorable the working environment, the higher the reliability of the selected Force Sensor should be.
4. Installation method: Whether you need to install "seamless" or use standard mode. Most Single Point Load Laod Cells require a flat and level surface for calibration and measurement. If it needs to be installed on existing equipment, special shape and size requirements, etc. need to be carefully considered.
5. Signal output: Different Single Point Load Laod Cells have different signal output methods, including analog voltage output, digital output, 4-20mA current loop output, etc. According to the signal type and data transmission method required by the equipment, select the most suitable Single Point Load Load Cell and signal output type.
6. Supplier credibility: Selecting a qualified supplier can ensure that the Single Point Load Laod Cell meets the standards, and provide sound warranty service and after-sales technical support.
Product Specification
Series: | LP80 |
Features: | Single load cell, Small Size |
Mounting Type: | Parallel beam installation |
Description: | Small size single load cell, load cell |
Model Number: | LP80002 |
Type: | Load Cell |
Brand Name: | XG sengsor |
Place of Origin: | Guangdong, China |
Usage: | Weighing sensor, Weight |
Output: | 1.0m V/V, Analog Signal |
Theory: | Resistance, Resistance Sensor |
Product name: | Loadcell |
Rated output: | 1.0 0.15 Mv/v |
Capacity: | 5kg |
Output Resistance: | 1000 10 |
Material: | Aluminum Alloy |
Input resistance: | 1000 10 |
Specifications | ||
Rated Output | mv/v | 1.0±0.2 |
Non-linearity | %F.S | 0.05%F.S |
Hysteresis | %F.S | 0.05 |
Repeatability | %F.S | 0.05 |
Creep | %F.S/3min | 0.05 |
Temp.effect on zero | %F.S/10℃ | 0.05%F.S |
Temp.effect on span | %F.S/10℃ | 0.05%F.S |
Zero balance | mv/v | ±0.05 |
Input impedance | Ω | 1000±6 |
Output impedance | Ω | 1000±5 |
Insulation resistance | MΩ | ≥2000(100VDC) |
Recommended excitation voltage | VDC | 3~12 |
Allowed excitation voltage | VDC | 3~12 |
Compensated temp.Range | ℃ | -10℃~+40℃ |
Operating temp.Range | ℃ | 0℃~+40℃ |
Safe overload | %F.S | 120 |
Ultimate Overload | %F.S | 150 |
Connection | Excitation: Red:+ Black:- | |
Signal: Green:+ White:- | ||
| | |